only a small command set ------------------------ if you are missing something please add! x always means the axis number: above 1 1 below 1 2 inner 1 3 outer 1 4 above 2 5 below 2 6 inner 2 7 outer 2 8 ST -replies the status (4 means ok) xS -stops the axis x+y -moves the target x to (actual position)+y x-y -should be clear x0 -mops the target x but writes no 0 into the position register!!!! x=N -answer: E - target at endswitch N - target not at endswitch xP21R -reads the position of axis x xP21Sy -sets the value y as position for axis x setting parameters described in the manual: xP03=y -sets the parameter P03 of axis x to y -> attention: some prameters need a correction xP03 -lets you edit parameter P03 of axis x xP03R -shows the actual parameter some target specific commands: after switching off and on you have to initialize the endswitch box: controler: MONITORBETRIEB type: H I A051 --- load a standart paramer setting (given in the eprom) type NP --- after exchanging the EPROM check the IESn parameter it has to be set to 0 IES0 dont check the amplifiers