/* =================================================================== Last Revision: K. Ehret 15.May.98 In this file all standard settings for the A200/SY127 HV-Power supply are stored together with the description of groups and channels. One can change this data just by editing this file. Since this file is read by the hv control program, please respect this rules: - this file should not contain lines with more than 80 characters - no line but the last line before the data should have an '&' or '@' as it's first character - do not change the structure of the data, e. g. don't fill in blank lines or other comments than the provided ones - do not use blanks in the comment on the channels For each channel there are stored nine values: V0, I0, trip settings, channel to group assignements, ramp up rate, ramp down rate, V1, I1 and a description string. The data structure is as followes: For each channel there is one line. The first value is V0 in V, the second I0 in uA, the third the trip-tolerance-time in tenth of a second the fourth represents the channel to group asignements (A200-manual p. 7: 0.bit: All, 1.bit: A, 2.bit: B etc.) the 5.th value gives the ramp-up rate, the 6.th the ramp-down rate, 7.th V1 in V and 8.th I1 in uA. =============================================== || Do not use blanks in the channel comment! || =============================================== ========================================================================*/ & Group Description Group-ALL: all-40-ch Group-A: 8-Triggercounter Group-B: 8-Hodoscopes Group-C: 8-Vetos Group-D: spare_I Group-E: spare_II Group-F: not-used Group-G: not-used @ Beginning of data 1250 1500 30 3 100 300 1400 3000 channel-00: trigger_counter03 1090 1400 30 3 100 300 1400 3000 channel-01: trigger_counter06 1000 1400 30 3 100 300 1400 3000 channel-02: trigger_counter09 1210 1500 30 3 100 300 1400 3000 channel-03: trigger_counter12 1100 1400 30 3 100 300 1400 3000 channel-04: trigger_counter15 1150 1450 30 3 100 300 1400 3000 channel-05: trigger_counter18 1200 1450 30 3 100 300 1400 3000 channel-06: trigger_counter21 1220 1500 30 3 100 300 1400 3000 channel-07: trigger_counter24 1224 1400 30 5 100 300 1400 3000 channel-08: small_1 1183 1400 30 5 100 300 1400 3000 channel-09: small_2 1242 1400 30 5 100 300 1400 3000 channel-10: small_3 1200 1450 30 5 100 300 1400 3000 channel-11: small_4 1310 1500 30 5 100 300 1400 3000 channel-12: large_1 1110 1450 30 5 100 300 1400 3000 channel-13: large_2 1095 1400 30 5 100 300 1400 3000 channel-14: large_3 1061 1400 30 5 100 300 1400 3000 channel-15: large_4 1080 1400 30 9 100 300 1400 3000 channel-16: veto_1 1070 1400 30 9 100 300 1400 3000 channel-17: veto_2 1240 1400 30 9 100 300 1400 3000 channel-18: veto_3 1150 1400 30 9 100 300 1400 3000 channel-19: veto_4 1280 1400 30 9 100 300 1400 3000 channel-20: veto_5 1200 1400 30 9 100 300 1400 3000 channel-21: veto_6 1280 2000 30 9 100 300 1400 3000 channel-22: veto_7 1110 2000 30 9 100 300 1400 3000 channel-23: veto_8 0 1000 30 17 100 300 1400 3000 channel-24: spare 0 1000 30 17 100 300 1400 3000 channel-25: spare 0 2000 30 17 100 300 1400 3000 channel-26: spare 0 2000 30 17 100 300 1400 3000 channel-27: spare 0 1000 30 17 100 300 1400 3000 channel-28: spare 0 1000 30 17 100 300 1400 3000 channel-29: spare 0 1000 30 17 100 300 1400 2000 channel-30: spare 0 1000 30 17 100 300 1400 2000 channel-31: spare 0 0 30 33 100 300 0 0 channel-32: dontuseposhv 0 0 30 33 100 300 0 0 channel-33: dontuseposhv 0 0 30 33 100 300 0 0 channel-34: dontuseposhv 0 0 30 33 100 300 0 0 channel-35: dontuseposhv 0 0 30 33 100 300 0 0 channel-36: dontuseposhv 0 0 30 33 100 300 0 0 channel-37: dontuseposhv 0 0 30 33 100 300 0 0 channel-38: dontuseposhv 0 0 30 33 100 300 0 0 channel-39: dontuseposhv