/* ============================================================================ Last Revision: K. Ehret/S. Spratte Feb. 19th 1999 In this file all standard settings for the A200/SY127 HV-Power supply are stored together with the description of groups and channels. One can change this data just by editing this file. Since this file is read by the hv control program, please respect this rules: - this file should not contain lines with more than 80 characters - no line but the last line before the data should have an '&' or '@' as it's first character - do not change the structure of the data, e. g. don't fill in blank lines or other comments than the provided ones - do not use blanks in the comment on the channels For each channel there are stored nine values: V0, I0, trip settings, channel to group assignements, ramp up rate, ramp down rate, V1, I1 and a description string. The data structure is as followes: For each channel there is one line. The first value is V0 in V, the second I0 in uA, the third the trip-tolerance-time in tenth of a second the fourth represents the channel to group asignements (A200-manual p. 7: 0.bit: All, 1.bit: A, 2.bit: B etc.) the 5.th value gives the ramp-up rate, the 6.th the ramp-down rate, 7.th V1 in V and 8.th I1 in uA. =============================================== || Do not use blanks in the channel comment! || =============================================== MAIN HV CONTROL UNIT WAS EXCHANGED AT 12/02/1999 !!! UNITS WITH THE BROKEN CHANNELS WERE REMOVED ON FEB. 19TH !!! =============================================================================*/ & Group Description Group-ALL: all-40-ch Group-A: 8-Triggercounter Group-B: 8-Hodoscopes Group-C: 8-Vetos Group-D: Si-Pad Group-E: spare_II Group-F: not-used Group-G: not-used @ Beginning of data 1470 600 30 5 100 300 1600 3000 channel-00: hodI_1 1380 600 30 5 100 300 1600 3000 channel-01: hodI_2 1370 600 30 5 100 300 1600 3000 channel-02: hodI_3 1510 600 30 5 100 300 1600 3000 channel-03: hodI_4 1550 600 30 5 100 300 1600 3000 channel-04: hodII_1 1300 600 30 5 100 300 1600 3000 channel-05: hodII_2 1450 600 30 5 100 300 1600 3000 channel-06: hodII_3 1330 600 30 5 100 300 1600 3000 channel-07: hodII_4 1400 600 30 9 100 300 1600 3000 channel-08: veto_1 1330 600 30 9 100 300 1600 3000 channel-09: veto_2 1250 600 30 9 100 300 1600 3000 channel-10: veto_3 1380 600 30 9 100 300 1600 3000 channel-11: veto_4 1370 600 30 9 100 300 1600 3000 channel-12: veto_5 1310 600 30 9 100 300 1600 3000 channel-13: veto_6 1420 600 30 9 100 300 1600 3000 channel-14: veto_7 1270 600 30 9 100 300 1600 3000 channel-15: veto_8 0 20 30 2 100 300 1600 3000 channel-16: spare 0 20 30 2 100 300 1600 3000 channel-17: spare 0 20 30 2 100 300 1600 3000 channel-18: spare 0 20 30 2 100 300 1600 3000 channel-19: spare 0 20 30 0 100 300 1600 3000 channel-20: nc 0 20 30 0 100 300 1600 3000 channel-21: nc 0 20 30 0 100 300 1600 3000 channel-22: nc 0 20 30 0 100 300 1600 3000 channel-23: nc 0 20 30 0 100 300 1600 3000 channel-24: nc 0 20 30 0 100 300 1600 3000 channel-25: nc 0 20 30 0 100 300 1600 3000 channel-26: nc 0 20 30 0 100 300 1600 3000 channel-27: nc 0 20 30 0 100 300 1600 3000 channel-28: nc 0 20 30 0 100 300 1600 3000 channel-29: nc 0 20 30 0 100 300 1600 3000 channel-30: nc 0 20 30 0 100 300 1600 3000 channel-31: nc 0 0 30 32 100 300 0 0 channel-32: dontuseposhv 0 0 30 32 100 300 0 0 channel-33: dontuseposhv 0 0 30 32 100 300 0 0 channel-34: dontuseposhv 0 0 30 32 100 300 0 0 channel-35: dontuseposhv 0 0 30 32 100 300 0 0 channel-36: dontuseposhv 0 0 30 32 100 300 0 0 channel-37: dontuseposhv 0 0 30 32 100 300 0 0 channel-38: dontuseposhv 0 0 30 32 100 300 0 0 channel-39: dontuseposhv