Module m1-3-01 ================ OUTPUT FROM CHECKDBS PROGRAM ============================ ---> INPUT file install-dbs/m1-3-01 ---> Number of valid lines read: 19 ---> line 2: MOD NAME L5M0508 ---> line 3: MOD TYPE mc1-10/2-1 ---> line 4: MOD LAYER single ---> line 19: T 1 .....DCWC.W..WW. ---> line 20: T 2 XXXXXXXXXXXXXXXX ---> line 21: T 3 XXXXXXXXXXXXXXXX ---> line 22: T 4 XXXXXXXXXXXXXXXX ---> line 23: T 5 XXXXXXXXXXXXXXXX ---> line 24: T 6 XXXXXXXXXXXXXXXX ---> line 25: T 7 XXXXXXXXXXXXXXXX ---> line 26: T 8 XXXXXXXXXXXXXXXX ---> line 27: B 1 C..WW..C.CD....W ---> line 28: B 2 XXXXXXXXXXXXXXXX ---> line 29: B 3 XXXXXXXXXXXXXXXX ---> line 30: B 4 XXXXXXXXXXXXXXXX ---> line 31: B 5 XXXXXXXXXXXXXXXX ---> line 32: B 6 XXXXXXXXXXXXXXXX ---> line 33: B 7 XXXXXXXXXXXXXXXX ---> line 34: B 8 XXXXXXXXXXXXXXXX ---> MP module name is: L5M0508 ---> MP module type is: mc1-10/2-1 ---> MP module layer is: single DRAWING of the module from TOP =============================== X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X . . d w . . w . X X X X X X X X X X X X X X X X X X X X X X X X . . . c c w . w X X X X X X X X X X X X X X X X X X X X X X X X DRAWING of the module from BOTTOM ================================= X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X w . . c c . w . X X X X X X X X X X X X X X X X X X X X X X X X . . d . . w . c SIGNAL CONNECTOR ASSIGNMENT =========================== m1-3-01-09 (001-016) BOT 1 m1-3-01-10 (001-016) TOP 1 FULL DATABASE FILE ================== *============================================================================== MOD NAME L5M0508 MOD TYPE mc1-10/2-1 MOD LAYER single *============================================================================== * Code definition * * . = Channel ok * W = Channel Warm (looks it will recover) * H = Channel Hot * D = Channel Dead (no signal seen) * C = Channel not Checked * X = Channel not eXisting * *============================================================================== * 1 4 8 12 16 * | | | | | *============================================================================== T 1 .....DCWC.W..WW. T 2 XXXXXXXXXXXXXXXX T 3 XXXXXXXXXXXXXXXX T 4 XXXXXXXXXXXXXXXX T 5 XXXXXXXXXXXXXXXX T 6 XXXXXXXXXXXXXXXX T 7 XXXXXXXXXXXXXXXX T 8 XXXXXXXXXXXXXXXX B 1 C..WW..C.CD....W B 2 XXXXXXXXXXXXXXXX B 3 XXXXXXXXXXXXXXXX B 4 XXXXXXXXXXXXXXXX B 5 XXXXXXXXXXXXXXXX B 6 XXXXXXXXXXXXXXXX B 7 XXXXXXXXXXXXXXXX B 8 XXXXXXXXXXXXXXXX *============================================================================== * * Module Test Results 24/02/99 * =================== * * Module Name: L5M0508 (Production) * ----------- m1-3-01 (Installation) * * Module Description: MC1- 10mm split wires (10s8), 2 x 16 channels * ------------------ * Both HV and signal cables are numbered as follows: * * View from Top Bottom * /---------/ \---------\ * / 1 / \ 1 \ * /=========/ base pl.\=========\ * 1 -> 16 16 <- 1 Wires in signal cable * * In the test sheet the top wire numbers must be reversed. * In the database scheme everything is correct. * * HV Training Results: * ------------------- * Training was done in ArCO2 50:50 at 2230 V. * All except the following HV groups had 0 nA dark current from the beginning. * * HV Grp Result * ------------------------------- * T1 640 -> 0 nA in 20 h * B1 20 -> 0 nA in 20 h * * Signal Test Results: * ------------------- * Signal testing means looking for cosmics with Hermes preamp. * For each cable two wires could not be checked because of attenuated preamp * inputs: top 7/9 and bottom 8/10. In addition bottom wire 1 could not be * read out. * All remaining wires except the following show good signals. * * Cable Wire Result * ------------------------------- * T1 15 noisy @ several kHz * 14 noisy @ several kHz * 11 noisy @ several kHz * 8 noisy @ several kHz * 6 dead * B1 4 noisy @ several kHz * 5 noisy @ several kHz * 11 dead * 16 noisy @ several kHz * * Summary: * ------- * 32 wires total * 7 wires noisy * 2 wires dead * 5 wires could not be checked ========= Module m1-3-01 (information from HERA-B hall) ====================== For module sector m1-3-01-09 (+y), ASDs are -m1-3-09-[01,01] Status of channels for each ASD: Online: -m1-3-09-01 ..........D..... (1234567890123456) Mass production: -m1-3-09-01 C..WW..C.CD....W (1234567890123456) Installation: -m1-3-09-01 ................ (1234567890123456) ASD distribution for module -m1-3-01, sector 09, +y +--------------+ | -m1-3-09-01 | | -m1-1-21-C07 | +--------------+ ----------------------------------------------------------------------------- For module sector m1-3-01-10 (-y), ASDs are -m1-3-10-[01,01] Status of channels for each ASD: Online: -m1-3-10-01 ................ (1234567890123456) Mass production: -m1-3-10-01 .....DCWC.W..WW. (1234567890123456) Installation: -m1-3-10-01 ................ (1234567890123456) ASD distribution for module -m1-3-01, sector 10, -y +--------------+ | -m1-3-10-01 | | -m1-1-01-C07 | +--------------+ -----------------------------------------------------------------------------