Module m4-3-10 ================ OUTPUT FROM CHECKDBS PROGRAM ============================ ---> INPUT file install-dbs/m4-3-10 ---> Number of valid lines read: 21 ---> line 2: MOD NAME MC-A22 ---> line 3: MOD TYPE mc4-5d24-21 ---> line 4: MOD LAYER single ---> line 20: T 1 ................ ---> line 21: T 2 ................ ---> line 22: T 3 ................ ---> line 23: T 4 XXXXXXXXXXXXXXXX ---> line 24: T 5 ................ ---> line 25: T 6 ................ ---> line 26: T 7 ................ ---> line 27: T 8 XXXXXXXXXXXXXXXX ---> line 28: T 9 XXXXXXXXXXXXXXXX ---> line 29: B 1 XXXXXXXXXXXXXXXX ---> line 30: B 2 XXXXXXXXXXXXXXXX ---> line 31: B 3 XXXXXXXXXXXXXXXX ---> line 32: B 4 XXXXXXXXXXXXXXXX ---> line 33: B 5 XXXXXXXXXXXXXXXX ---> line 34: B 6 XXXXXXXXXXXXXXXX ---> line 35: B 7 XXXXXXXXXXXXXXXX ---> line 36: B 8 XXXXXXXXXXXXXXXX ---> line 37: B 9 XXXXXXXXXXXXXXXX ---> MP module name is: MC-A22 ---> MP module type is: mc4-5d24-21 ---> MP module layer is: single DRAWING of the module from TOP =============================== . . . . . . . . . . . . . . . . . . . . . . . . X X X X X X X X . . . . . . . . . . . . . . . . . . . . . . . . X X X X X X X X . . . . . . . . . . . . . . . . . . . . . . . . X X X X X X X X . . . . . . . . . . . . . . . . . . . . . . . . X X X X X X X X DRAWING of the module from BOTTOM ================================= X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SIGNAL CONNECTOR ASSIGNMENT =========================== m4-3-10-03 (001-016) TOP 7 m4-3-10-03 (017-032) TOP 6 m4-3-10-03 (033-048) TOP 5 m4-3-10-04 (001-016) TOP 3 m4-3-10-04 (017-032) TOP 2 m4-3-10-04 (033-048) TOP 1 FULL DATABASE FILE ================== *============================================================================== MOD NAME MC-A22 MOD TYPE mc4-5d24-21 MOD LAYER single *============================================================================== * Code definition * * . = Channel ok * W = Channel Warm (looks it will recover) * H = Channel Hot * D = Channel Dead (no signal seen) * C = Channel not Checked * N = Channel Noisy * X = Channel not eXisting * *============================================================================== * 1 4 8 12 16 * | | | | | *============================================================================== T 1 ................ T 2 ................ T 3 ................ T 4 XXXXXXXXXXXXXXXX T 5 ................ T 6 ................ T 7 ................ T 8 XXXXXXXXXXXXXXXX T 9 XXXXXXXXXXXXXXXX B 1 XXXXXXXXXXXXXXXX B 2 XXXXXXXXXXXXXXXX B 3 XXXXXXXXXXXXXXXX B 4 XXXXXXXXXXXXXXXX B 5 XXXXXXXXXXXXXXXX B 6 XXXXXXXXXXXXXXXX B 7 XXXXXXXXXXXXXXXX B 8 XXXXXXXXXXXXXXXX B 9 XXXXXXXXXXXXXXXX *============================================================================== * * Module Test Results 04/08/99 * =================== * * Module Name: MC-A22 * ----------- * * Module Description: MC4+ * ------------------ * * HV Training Results: * ------------------- * o training was done in Ar/CO2 at 1850V * * Signal Test Results: * ------------------- * o rate of noisy channel * * Summary: * ------- ========= Module m4-3-10 (information from HERA-B hall) ====================== For module sector m4-3-10-03 (+y), ASDs are +m4-3-03-[04,06] List of cut small HV groups: +m4-3-10-03-2 Status of channels for each ASD: Online: +m4-3-03-04 DDDDDDDDDDDDDDDD +m4-3-03-05 DDDDDDDDDDDDDDDD +m4-3-03-06 DDDDDDDDDDDDDDDD (1234567890123456) Mass production: +m4-3-03-04 ................ +m4-3-03-05 ................ +m4-3-03-06 ................ (1234567890123456) Installation: +m4-3-03-04 ................ +m4-3-03-05 ................ +m4-3-03-06 ................ (1234567890123456) ASD distribution for module +m4-3-10, sector 03, +y +--------------+--------------+--------------+ | +m4-3-03-06 | +m4-3-03-05 | +m4-3-03-04 | | +m4-1-63-A12 | +m4-1-62-C12 | +m4-1-62-B12 | +--------------+--------------+--------------+ | | | | | | | | +--------------+--------------+--------------+ ----------------------------------------------------------------------------- For module sector m4-3-10-04 (+y), ASDs are +m4-3-04-[04,06] Status of channels for each ASD: Online: +m4-3-04-04 DDDDDDDDDDDDDDDD +m4-3-04-05 DDDDDDDDDDDDDDDD +m4-3-04-06 DDDDDDDDDDDDDDDD (1234567890123456) Mass production: +m4-3-04-04 ................ +m4-3-04-05 ................ +m4-3-04-06 ................ (1234567890123456) Installation: +m4-3-04-04 ................ +m4-3-04-05 ................ +m4-3-04-06 ................ (1234567890123456) ASD distribution for module +m4-3-10, sector 04, +y +--------------+--------------+--------------+ | | | | | | | | +--------------+--------------+--------------+ | +m4-3-04-06 | +m4-3-04-05 | +m4-3-04-04 | | +m4-1-63-A11 | +m4-1-62-C11 | +m4-1-62-B11 | +--------------+--------------+--------------+ -----------------------------------------------------------------------------