Module m8-2-12 ================ OUTPUT FROM CHECKDBS PROGRAM ============================ ---> INPUT file install-dbs/m8-2-12 ---> Number of valid lines read: 19 ---> line 2: MOD NAME L5M0824 ---> line 3: MOD TYPE mc8-5d32-21 ---> line 4: MOD LAYER single ---> line 19: T 1 .............DSD ---> line 20: T 2 ................ ---> line 21: T 3 ........W.W..... ---> line 22: T 4 ........H.W..... ---> line 23: T 5 ................ ---> line 24: T 6 ................ ---> line 25: T 7 ................ ---> line 26: T 8 ................ ---> line 27: B 1 XXXXXXXXXXXXXXXX ---> line 28: B 2 XXXXXXXXXXXXXXXX ---> line 29: B 3 XXXXXXXXXXXXXXXX ---> line 30: B 4 XXXXXXXXXXXXXXXX ---> line 31: B 5 XXXXXXXXXXXXXXXX ---> line 32: B 6 XXXXXXXXXXXXXXXX ---> line 33: B 7 XXXXXXXXXXXXXXXX ---> line 34: B 8 XXXXXXXXXXXXXXXX ---> MP module name is: L5M0824 ---> MP module type is: mc8-5d32-21 ---> MP module layer is: single DRAWING of the module from TOP =============================== . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d d . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . s . . . . . . . . . . . . w w . . . . . . h w . . DRAWING of the module from BOTTOM ================================= X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SIGNAL CONNECTOR ASSIGNMENT =========================== FULL DATABASE FILE ================== *============================================================================== MOD NAME L5M0824 MOD TYPE mc8-5d32-21 MOD LAYER single *============================================================================== * Code definition * * . = Channel ok * W = Channel Warm (looks it will recover) * H = Channel Hot * D = Channel Dead (no signal seen) * C = Channel not Checked * X = Channel not eXisting * *============================================================================== * 1 4 8 12 16 * | | | | | *============================================================================== T 1 .............DSD T 2 ................ T 3 ........W.W..... T 4 ........H.W..... T 5 ................ T 6 ................ T 7 ................ T 8 ................ B 1 XXXXXXXXXXXXXXXX B 2 XXXXXXXXXXXXXXXX B 3 XXXXXXXXXXXXXXXX B 4 XXXXXXXXXXXXXXXX B 5 XXXXXXXXXXXXXXXX B 6 XXXXXXXXXXXXXXXX B 7 XXXXXXXXXXXXXXXX B 8 XXXXXXXXXXXXXXXX *============================================================================== * * Module Test Results 17/09/99 * =================== * * Module Name: L5M0824 (Production) * ----------- m8-2-12 (Installation) * * Module Description: MC8+ standard (5d32), 2 x 64 channels * ------------------ * Both HV and signal cables are numbered as follows: * * View from Top Bottom * /---------/ \---------\ * / 5 6 7 8 / \ \ * / 1 2 3 4 / \ \ * /=========/ base pl. \=========\ * 1 -> 16 Wires in signal cable * * HV Training Results: * ------------------- * Training was done in ArCO2 50:50 at 1850 V. * All except the following HV groups had 0 nA dark current after training. * * HV Grp Result * ------------------------------- * T1 wire 15 short -> disconnected * * Signal Test Results: * ------------------- * Signal testing means looking for Ru106 signals with Hermes preamp. * All wires except the following show good signals: * * Cable Wire Result * ------------------------------- * T1 14,16 dead * 15 disconnected * T3 9,11 noisy > 500 kHz (I=0) * T4 9 noisy 1 MHz (I=0) * 11 noisy 500 kHz (I=0) * * Summary: * ------- * 128 wires total * 4 wires noisy (1 hot) * 2 wires dead * 1 wire disconnected ========= Module m8-2-12 (information from HERA-B hall) ====================== For module sector m8-2-12-03 (+y), ASDs are +m8-2-03-[04,07] Status of channels for each ASD: Online: +m8-2-03-04 .....DD......... +m8-2-03-05 D............... +m8-2-03-06 .......H........ +m8-2-03-07 ................ (1234567890123456) Mass production: +m8-2-03-04 ................ +m8-2-03-05 ................ +m8-2-03-06 ................ +m8-2-03-07 ................ (1234567890123456) Installation: +m8-2-03-04 ................ +m8-2-03-05 ................ +m8-2-03-06 ................ +m8-2-03-07 ................ (1234567890123456) ASD distribution for module +m8-2-12, sector 03, +y +--------------+--------------+--------------+--------------+ | +m8-2-03-07 | +m8-2-03-06 | +m8-2-03-05 | +m8-2-03-04 | | +m8-1-62-A04 | +m8-1-62-A03 | +m8-1-62-A02 | +m8-1-62-A01 | +--------------+--------------+--------------+--------------+ | | | | | | | | | | +--------------+--------------+--------------+--------------+ ----------------------------------------------------------------------------- For module sector m8-2-12-04 (+y), ASDs are +m8-2-04-[04,07] Status of channels for each ASD: Online: +m8-2-04-04 ................ +m8-2-04-05 ................ +m8-2-04-06 ................ +m8-2-04-07 .D.............. (1234567890123456) Mass production: +m8-2-04-04 .....W.H........ +m8-2-04-05 .....W.W........ +m8-2-04-06 ................ +m8-2-04-07 DSD............. (1234567890123456) Installation: +m8-2-04-04 ................ +m8-2-04-05 ................ +m8-2-04-06 ................ +m8-2-04-07 ................ (1234567890123456) ASD distribution for module +m8-2-12, sector 04, +y +--------------+--------------+--------------+--------------+ | | | | | | | | | | +--------------+--------------+--------------+--------------+ | +m8-2-04-07 | +m8-2-04-06 | +m8-2-04-05 | +m8-2-04-04 | | +m8-1-62-A08 | +m8-1-62-A07 | +m8-1-62-A06 | +m8-1-62-A05 | +--------------+--------------+--------------+--------------+ -----------------------------------------------------------------------------