Module m8-3-14 ================ OUTPUT FROM CHECKDBS PROGRAM ============================ ---> INPUT file install-dbs/m8-3-14 ---> Number of valid lines read: 19 ---> line 2: MOD NAME L5M0832 ---> line 3: MOD TYPE mc8-5d24-22 ---> line 4: MOD LAYER single ---> line 19: T 1 ...........H.... ---> line 20: T 2 ................ ---> line 21: T 3 .........W...... ---> line 22: T 4 XXXXXXXXXXXXXXXX ---> line 23: T 5 ................ ---> line 24: T 6 ................ ---> line 25: T 7 ................ ---> line 26: T 8 XXXXXXXXXXXXXXXX ---> line 27: B 1 XXXXXXXXXXXXXXXX ---> line 28: B 2 XXXXXXXXXXXXXXXX ---> line 29: B 3 XXXXXXXXXXXXXXXX ---> line 30: B 4 XXXXXXXXXXXXXXXX ---> line 31: B 5 XXXXXXXXXXXXXXXX ---> line 32: B 6 XXXXXXXXXXXXXXXX ---> line 33: B 7 XXXXXXXXXXXXXXXX ---> line 34: B 8 XXXXXXXXXXXXXXXX ---> MP module name is: L5M0832 ---> MP module type is: mc8-5d24-22 ---> MP module layer is: single DRAWING of the module from TOP =============================== . . . . . . . . . . . . . . . . . . . . . . . . X X X X X X X X . . . . . . . . . . . . . . . . . . . . . . . . X X X X X X X X . . . . . h . . . . . . . . . . . . . . w . . . X X X X X X X X . . . . . . . . . . . . . . . . . . . . . . . . X X X X X X X X DRAWING of the module from BOTTOM ================================= X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SIGNAL CONNECTOR ASSIGNMENT =========================== FULL DATABASE FILE ================== *============================================================================== MOD NAME L5M0832 MOD TYPE mc8-5d24-22 MOD LAYER single *============================================================================== * Code definition * * . = Channel ok * W = Channel Warm (looks it will recover) * H = Channel Hot * D = Channel Dead (no signal seen) * C = Channel not Checked * X = Channel not eXisting * *============================================================================== * 1 4 8 12 16 * | | | | | *============================================================================== T 1 ...........H.... T 2 ................ T 3 .........W...... T 4 XXXXXXXXXXXXXXXX T 5 ................ T 6 ................ T 7 ................ T 8 XXXXXXXXXXXXXXXX B 1 XXXXXXXXXXXXXXXX B 2 XXXXXXXXXXXXXXXX B 3 XXXXXXXXXXXXXXXX B 4 XXXXXXXXXXXXXXXX B 5 XXXXXXXXXXXXXXXX B 6 XXXXXXXXXXXXXXXX B 7 XXXXXXXXXXXXXXXX B 8 XXXXXXXXXXXXXXXX *============================================================================== * * Module Test Results 17/09/99 * =================== * * Module Name: L5M0832 (Production) * ----------- m8-3-14 (Installation) * * Module Description: MC8+ 5mm section 7/8 (5d24), 2 x 48 channels * ------------------ * Both HV and signal cables are numbered as follows: * * View from Top Bottom * /---------/ \---------\ * / 5 6 7 / \ \ * / 1 2 3 / \ \ * /=========/ base pl. \=========\ * 1 -> 16 Wires in signal cable * * HV Training Results: * ------------------- * Training was done in ArCO2 50:50 at 1850 V. * All except the following HV groups had 0 nA dark current after training. * * HV Grp Result * ------------------------------- * * Signal Test Results: * ------------------- * Signal testing means looking for Ru106 signals with Hermes preamp. * All wires except the following show good signals: * * Cable Wire Result * ------------------------------- * T1 12 noisy 2 MHz (I=0) * T3 10 noisy < 500 kHz (I=120nA) * * Summary: * ------- * 96 wires total * 2 wires noisy (1 hot) ========= Module m8-3-14 (information from HERA-B hall) ====================== For module sector m8-3-14-07 (+y), ASDs are +m8-3-07-[01,03] Status of channels for each ASD: Online: +m8-3-07-01 ................ +m8-3-07-02 ................ +m8-3-07-03 ................ (1234567890123456) Mass production: +m8-3-07-01 ................ +m8-3-07-02 ................ +m8-3-07-03 ................ (1234567890123456) Installation: +m8-3-07-01 ................ +m8-3-07-02 ................ +m8-3-07-03 ................ (1234567890123456) ASD distribution for module +m8-3-14, sector 07, +y +--------------+--------------+--------------+ | +m8-3-07-03 | +m8-3-07-02 | +m8-3-07-01 | | +m8-1-64-A05 | +m8-1-64-A04 | +m8-1-64-A03 | +--------------+--------------+--------------+ ----------------------------------------------------------------------------- For module sector m8-3-14-08 (+y), ASDs are +m8-3-08-[01,03] Status of channels for each ASD: Online: +m8-3-08-01 .D......D....... +m8-3-08-02 ..D............. +m8-3-08-03 H............... (1234567890123456) Mass production: +m8-3-08-01 ......W......... +m8-3-08-02 ................ +m8-3-08-03 ....H........... (1234567890123456) Installation: +m8-3-08-01 ................ +m8-3-08-02 ................ +m8-3-08-03 ................ (1234567890123456) ASD distribution for module +m8-3-14, sector 08, +y +--------------+--------------+--------------+ | +m8-3-08-03 | +m8-3-08-02 | +m8-3-08-01 | | +m8-1-64-A02 | +m8-1-63-A09 | +m8-1-63-A08 | +--------------+--------------+--------------+ -----------------------------------------------------------------------------