Module t2-2-17 ================ OUTPUT FROM CHECKDBS PROGRAM ============================ ---> INPUT file install-dbs/t2-2-17 ---> Number of valid lines read: 21 ---> line 2: MOD NAME L5M0547 ---> line 3: MOD TYPE tc-104 ---> line 4: MOD LAYER double ---> line 19: T 1 ................ ---> line 20: T 2 H............... ---> line 21: T 3 ................ ---> line 22: T 4 ................ ---> line 23: T 5 ..S....S........ ---> line 24: T 6 ..H.....S...XSX. ---> line 25: T 7 XXXXXXXXXXXXXXXX ---> line 26: T 8 XXXXXXXXXXXXXXXX ---> line 27: T 9 ..XXXXXXXXXXXXXX ---> line 28: B 1 XXXXXXXXXXXXXXXX ---> line 29: B 2 XXXXXXXXXXXXXXXX ---> line 30: B 3 XXXXXXXXXXXXXXXX ---> line 31: B 4 XXXXXXXXXXXXXXXX ---> line 32: B 5 XXXXXXXXXXXXXXXX ---> line 33: B 6 XXXXXXXXXXXXXXXX ---> line 34: B 7 XXXXXXXXXXXXXXXX ---> line 35: B 8 XXXXXXXXXXXXXXXX ---> line 36: B 9 XXXXXXXXXXXXXXXX ---> MP module name is: L5M0547 ---> MP module type is: tc-104 ---> MP module layer is: double DRAWING of the module from TOP =============================== . . . . . . . . . . . . . . . . . s . . . . . . X X X X X X X X . . . . . . . . . . . . . . . . . . . . . . . s X X X X X X X X ./. . . . . . . . . . . . . . . . s . . . h . . X X X X X X X X X ./. . . . h . . . . . . . . . . . . . . . . . s X X X X X X X X X DRAWING of the module from BOTTOM ================================= X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X\X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X\X SIGNAL CONNECTOR ASSIGNMENT =========================== t2-2-17-02 (001-016) TOP 1 t2-2-17-02 (017-032) TOP 2 t2-2-17-02 (033-048) TOP 3 t2-2-17-02 (049-064) TOP 4 t2-2-17-02 (065-080) TOP 5 t2-2-17-02 (081-096) TOP 6 FULL DATABASE FILE ================== *============================================================================== MOD NAME L5M0547 MOD TYPE tc-104 MOD LAYER double *============================================================================== * Code definition * * . = Channel ok * W = Channel Warm (looks it will recover) * H = Channel Hot * D = Channel Dead (no signal seen) * C = Channel not Checked * X = Channel not eXisting * *============================================================================== * 1 4 8 12 16 * | | | | | *============================================================================== T 1 ................ T 2 H............... T 3 ................ T 4 ................ T 5 ..S....S........ T 6 ..H.....S...XSX. T 7 XXXXXXXXXXXXXXXX T 8 XXXXXXXXXXXXXXXX T 9 ..XXXXXXXXXXXXXX B 1 XXXXXXXXXXXXXXXX B 2 XXXXXXXXXXXXXXXX B 3 XXXXXXXXXXXXXXXX B 4 XXXXXXXXXXXXXXXX B 5 XXXXXXXXXXXXXXXX B 6 XXXXXXXXXXXXXXXX B 7 XXXXXXXXXXXXXXXX B 8 XXXXXXXXXXXXXXXX B 9 XXXXXXXXXXXXXXXX *============================================================================== * * Module Test Results 21/04/99 * ================== * * Module Name: L5M0547 (Production) * ----------- t2-2-17 (Installation) * * Module Description: TC- 5mm below p-beam (5d24), 1 x 96 channels * ------------------ * Signal cables are numbered as follows: * * View from Top Bottom * /---------/ \---------\ * / 2 4 6 / \ \ * / 1 3 5 / \ \ * /=========/ base pl. \=========\ * 1 -> 16 16 <- 1 Wires in signal cable * * HV cables are numbered as follows: * * View from Top Bottom * /---------/ \---------\ * / 5 6 7 / \ \ * / 1 2 3 / \ \ * /=========/ base pl. \=========\ * * The wire numbers used in the test sheet are OK. * * HV Training Results: * ------------------- * Training was done in ArCO2 50:50 at 1850 V. * HV stability can only be reached by pressing the module to the flat surface * of the litter. A previous test without this (31/03/99) failed completely. * All except the following HV groups had 0 nA dark current from the beginning. * * HV Grp Result * ------------------------------- * T1 500 -> 540 nA in 20 h * T3 560 -> 90 nA in 20 h * T6 340 -> 120 nA in 20 h * T7 980 ->1200 nA in 20 h, 0 nA after disconnecting HV wire 4 * * Signal Test Results: * ------------------- * Signal testing means looking for cosmics with Hermes preamp. * All remaining wires except the following show good signals: * * Cable Wire Result * ------------------------------- * T2 1 hot > 1 MHz, not disconnected (current < 1000 nA) * T5 3 DISCONNECTED after HV-board installation (short) * 8 hot > 1 MHz, DISCONNECTED * T6 3 hot > 1 MHz, not disconnected * 9 DISCONNECTED after HV-board installation (short) * 14 DISCONNECTED after HV-board installation (short) * * Summary: * ------- * 96 wires total * 2 wires noisy (2 hot) * 4 wires disconnected ========= Module t2-2-17 (information from HERA-B hall) ====================== For module sector t2-2-17-02 (-y), ASDs are -t2-2-02-[35,40] Status of channels for each ASD: Online: -t2-2-02-35 ................ -t2-2-02-36 ................ -t2-2-02-37 ................ -t2-2-02-38 ................ -t2-2-02-39 H.D....D........ -t2-2-02-40 ........D....D.. (1234567890123456) Mass production: -t2-2-02-35 ................ -t2-2-02-36 H............... -t2-2-02-37 ................ -t2-2-02-38 ................ -t2-2-02-39 ..S....S........ -t2-2-02-40 ..H.....S....S.. (1234567890123456) Installation: -t2-2-02-35 ................ -t2-2-02-36 ................ -t2-2-02-37 ................ -t2-2-02-38 ................ -t2-2-02-39 ................ -t2-2-02-40 ................ (1234567890123456) ASD distribution for module -t2-2-17, sector 02, -y +--------------+--------------+--------------+ | -t2-2-02-36 | -t2-2-02-38 | -t2-2-02-40 | | -t2-1-11-C09 | -t2-2-12-A02 | -t2-2-12-A04 | +--------------+--------------+--------------+ | -t2-2-02-35 | -t2-2-02-37 | -t2-2-02-39 | | -t2-1-11-C08 | -t2-2-12-A01 | -t2-2-12-A03 | +--------------+--------------+--------------+ -----------------------------------------------------------------------------