Module t2-2-19 ================ OUTPUT FROM CHECKDBS PROGRAM ============================ ---> INPUT file install-dbs/t2-2-19 ---> Number of valid lines read: 21 ---> line 2: MOD NAME L5M0538 ---> line 3: MOD TYPE tc-105 ---> line 4: MOD LAYER double ---> line 19: T 1 .....S.....S.... ---> line 20: T 2 ................ ---> line 21: T 3 ................ ---> line 22: T 4 ................ ---> line 23: T 5 .S.............. ---> line 24: T 6 ............X.X. ---> line 25: T 7 XXXXXXXXXXXXXXXX ---> line 26: T 8 XXXXXXXXXXXXXXXX ---> line 27: T 9 ..XXXXXXXXXXXXXX ---> line 28: B 1 XXXXXXXXXXXXXXXX ---> line 29: B 2 XXXXXXXXXXXXXXXX ---> line 30: B 3 XXXXXXXXXXXXXXXX ---> line 31: B 4 XXXXXXXXXXXXXXXX ---> line 32: B 5 XXXXXXXXXXXXXXXX ---> line 33: B 6 XXXXXXXXXXXXXXXX ---> line 34: B 7 XXXXXXXXXXXXXXXX ---> line 35: B 8 XXXXXXXXXXXXXXXX ---> line 36: B 9 XXXXXXXXXXXXXXXX ---> MP module name is: L5M0538 ---> MP module type is: tc-105 ---> MP module layer is: double DRAWING of the module from TOP =============================== . . s . . . . . . . . . . . . . . . . . . . . . X X X X X X X X . s . . . . . . . . . . . . . . s . . . . . . . X X X X X X X X ./. . . . . . . . . . . . . . . . . . . . . . . X X X X X X X X X ./. . . . . . . . . . . . . . . . . . . . . . . X X X X X X X X X DRAWING of the module from BOTTOM ================================= X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X\X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X\X SIGNAL CONNECTOR ASSIGNMENT =========================== t2-2-19-02 (001-016) TOP 1 t2-2-19-02 (017-032) TOP 2 t2-2-19-02 (033-048) TOP 3 t2-2-19-02 (049-064) TOP 4 t2-2-19-02 (065-080) TOP 5 t2-2-19-02 (081-096) TOP 6 t2-2-19-02 (097-102) TOP 7 FULL DATABASE FILE ================== *============================================================================== MOD NAME L5M0538 MOD TYPE tc-105 MOD LAYER double *============================================================================== * Code definition * * . = Channel ok * W = Channel Warm (looks it will recover) * H = Channel Hot * D = Channel Dead (no signal seen) * C = Channel not Checked * X = Channel not eXisting * *============================================================================== * 1 4 8 12 16 * | | | | | *============================================================================== T 1 .....S.....S.... T 2 ................ T 3 ................ T 4 ................ T 5 .S.............. T 6 ............X.X. T 7 XXXXXXXXXXXXXXXX T 8 XXXXXXXXXXXXXXXX T 9 ..XXXXXXXXXXXXXX B 1 XXXXXXXXXXXXXXXX B 2 XXXXXXXXXXXXXXXX B 3 XXXXXXXXXXXXXXXX B 4 XXXXXXXXXXXXXXXX B 5 XXXXXXXXXXXXXXXX B 6 XXXXXXXXXXXXXXXX B 7 XXXXXXXXXXXXXXXX B 8 XXXXXXXXXXXXXXXX B 9 XXXXXXXXXXXXXXXX *============================================================================== * * Module Test Results 21/04/99 * ================== * * Module Name: L5M0538 (Production) * ----------- t2-2-19 (Installation) * * Module Description: TC- 5mm overlap below p-beam (5d27spec), 1 x 102 channels * ------------------ wire 25-27 ML 1a not connected * wire 25-26 ML 1b not connected * wire 25 ML 2a not connected -> 96 wires read out * Signal cables are numbered as follows: * * View from Top Bottom * /---------/ \---------\ * / 2 4 6 / \ \ * / 1 3 5 / \ \ * /=========/ base pl. \=========\ * 1 -> 16 16 <- 1 Wires in signal cable * * HV cables are numbered as follows: * * View from Top Bottom * /---------/ \---------\ * / 5 6 7 / \ \ * / 1 2 3 / \ \ * /=========/ base pl. \=========\ * * The wire numbers used in the test sheet are OK. * * HV Training Results: * ------------------- * Training was done in ArCO2 50:50 at 1850 V. * HV stability can only be reached by pressing the module to the flat surface * of the litter. * All except the following HV groups had 0 nA dark current from the beginning. * * HV Grp Result * ------------------------------- * T2 560 -> 0 nA in 7 h * T5 4900 ->2400 nA in 7 h, 800 nA after disconnecting HV wires 3,6 * T6 1660 -> 240 nA in 7 h * T7 4100 ->2300 nA in 7 h, 800 nA after disconnecting HV wire 4 * * Signal Test Results: * ------------------- * Signal testing means looking for cosmics with Hermes preamp. * All remaining wires except the following show good signals: * * Cable Wire Result * ------------------------------- * T1 6,12 hot > 1 MHz, DISCONNECTED * T5 8 DISCONNECTED * * Summary: * ------- * 96 wires total * 3 wires disconnected ========= Module t2-2-19 (information from HERA-B hall) ====================== For module sector t2-2-19-02 (-y), ASDs are -t2-2-02-[41,47] List of cut wires during module installation: -t2-2-19-02-07-06 cut Status of channels for each ASD: Online: -t2-2-02-41 D...DD.....D.... -t2-2-02-42 ...........H.... -t2-2-02-43 ....D........... -t2-2-02-44 H..H.......H.DHD -t2-2-02-45 .D.............. -t2-2-02-46 ............D.D. -t2-2-02-47 DDDXDXXXXXXXXXXX (1234567890123456) Mass production: -t2-2-02-41 .....S.....S.... -t2-2-02-42 ................ -t2-2-02-43 ................ -t2-2-02-44 ................ -t2-2-02-45 .S.............. -t2-2-02-46 ............X.X. -t2-2-02-47 XXXXXXXXXXXXXXXX (1234567890123456) Installation: -t2-2-02-41 ................ -t2-2-02-42 ................ -t2-2-02-43 ................ -t2-2-02-44 ................ -t2-2-02-45 ...........I.... -t2-2-02-46 ................ -t2-2-02-47 ................ (1234567890123456) ASD distribution for module -t2-2-19, sector 02, -y +--------------+--------------+--------------+--------------+ | | -t2-2-02-43 | -t2-2-02-45 | -t2-2-02-47 | | | -t2-1-12-B09 | -t2-1-12-C07 | -t2-1-12-C09 | +--------------+--------------+--------------+--------------+ | -t2-2-02-41 | -t2-2-02-42 | -t2-2-02-44 | -t2-2-02-46 | | -t2-1-12-B07 | -t2-1-12-B08 | -t2-2-12-B01 | -t2-1-12-C08 | +--------------+--------------+--------------+--------------+ -----------------------------------------------------------------------------