ITR Chambers and Wafers of July 13, 2000

Installed Chambers:
MS01, MS03,
MS05, MS06,
MS10, MS11, MS12, MS13,
MS14,MS15
Back to Homepage
MS01
chamber label (new) wafer ID slow control channel remark
MS 01++1(0$^{\circ}$) K344 it/h/x/01/1/++1 new chamber
MS 01-+1(0$^{\circ}$) K348 it/h/x/01/1/-+1  
MS 01+-1(0$^{\circ}$) K363 it/h/x/01/1/+-1  
MS 01--1(0$^{\circ}$) K339 it/h/x/01/1/--1  
MS 01++2(-5$^{\circ}$) K343 it/h/x/01/1/++2  
MS 01-+2(-5$^{\circ}$) K337 it/h/x/01/1/-+2  
MS 01+-2(-5$^{\circ}$) K361 it/h/x/01/1/+-2  
MS 01--2(-5$^{\circ}$) K336 it/h/x/01/1/--2  
MS 01++3(+5$^{\circ}$) K342 it/h/x/01/2/++3  
MS 01-+3(+5$^{\circ}$) K334 it/h/x/01/2/-+3  
MS 01+-3(+5$^{\circ}$) K355 it/h/x/01/2/+-3 dead - $>$ 180$\mu$A @ 110V Cathode
MS 01--3(+5$^{\circ}$) K319 it/h/x/01/3/--3 frequent drift 'discharges', unusable
      connected to $\rightarrow$ hospital
      HV connection resoldered march 07
MS 01++4(0$^{\circ}$) K362 it/h/x/01/2/++4  
MS 01-+4(0$^{\circ}$) K333 it/h/x/01/2/-+4  
MS 01+-4(0$^{\circ}$) K359 it/h/x/01/2/+-4  
MS 01--4(0$^{\circ}$) K340 it/h/x/01/3/--4 frequent GEM sparks reappeared+
      high cathode current (130$\mu$A@420V)

MS03
chamber label (new) wafer ID slow control channel remark
MS 03++1(0$^{\circ}$) K350 it/h/x/03/1/++1  
MS 03-+1(0$^{\circ}$) K327 it/h/x/03/2/-+1  
MS 03+-1(0$^{\circ}$) K456 it/h/x/03/2/+-1  
MS 03--1(0$^{\circ}$) K455 it/h/x/03/1/--1  
MS 03++2(-5$^{\circ}$) K322 it/h/x/03/1/++2  
MS 03-+2(-5$^{\circ}$) K317 it/h/x/03/2/-+2  
MS 03+-2(-5$^{\circ}$) K326 it/h/x/03/3/+-2 drift connection bad
      to be checked in S-D
MS 03--2(-5$^{\circ}$) K454 it/h/x/03/1/--2 cathode problems, disconnected (either
      new kind diode problem or cable problem)
MS05
chamber label (new) wafer ID slow control channel remark
MS 05++1(0$^{\circ}$) K347 it/h/x/05/1/++1  
MS 05-+1(0$^{\circ}$) K335 it/h/x/05/1/-+1 Readout shows no signal
MS 05+-1(0$^{\circ}$) K357 it/h/x/05/1/+-1  
MS 05--1(0$^{\circ}$) K318 it/h/x/05/1/--1  

MS 05++2(+5$^{\circ}$)

K351 it/h/x/05/2/++2 connected to hospital
      cathode problems
MS 05-+2(+5$^{\circ}$) K356 it/h/x/05/2/-+2  
MS 05+-2(+5$^{\circ}$) K346 it/h/x/05/2/+-2  
MS 05--2(+5$^{\circ}$) K341 it/h/x/05/2/--2  
MS06
chamber label (new) wafer ID slow control channel remark
MS 06++1(0$^{\circ}$) K148 it/h/x/06/1/++1  
MS 06-+1(0$^{\circ}$) K 89 it/h/x/06/1/-+1  
MS 06+-1(0$^{\circ}$) K195 it/h/x/06/1/+-1  
MS 06--1(0$^{\circ}$) K206 it/h/x/06/1/--1  

MS 06++2(-5$^{\circ}$)

K202 it/h/x/06/2/++2  
MS 06-+2(-5$^{\circ}$) K122 it/h/x/06/2/-+2  
MS 06+-2(-5$^{\circ}$) K168 it/h/x/06/2/+-2  
MS 06--2(-5$^{\circ}$) K193 it/h/x/06/2/--2  

MS10
chamber label (new) wafer ID slow control channel remark
MS 10++1(0$^{\circ}$) K470 it/h/x/10/1/++1 textcolorgreenreplaced 06.03.2000
MS 10-+1(0$^{\circ}$) K 72 it/h/x/10/1/-+1 cathode shorts - dead
      maybe got confused with K75
MS 10+-1(0$^{\circ}$) K394 it/h/x/10/1/+-1 $\rightarrow$ GEM short removed, 06.03.2000
MS 10--1(0$^{\circ}$) K 78 it/h/x/10/5/--1 connected to hospital 07.07.2000
    cathode problems
MS 10++2(0$^{\circ}$) K401 it/h/x/10/2/++2  
MS 10-+2(0$^{\circ}$) K 75 it/h/x/10/2/-+2  
MS 10+-2(0$^{\circ}$) K403 it/h/x/10/1/+-2  
MS 10--2(0$^{\circ}$) K 40 it/h/x/10/2/--2  

MS 10++3(-5$^{\circ}$)

K411 it/h/x/10/1/++3  
MS 10-+3(-5$^{\circ}$) K 42 it/h/x/10/2/-+3  
MS 10+-3(-5$^{\circ}$) K400 it/h/x/10/2/+-3 drift connection resoldered, currents low
MS 10--3(-5$^{\circ}$) K 69 it/h/x/10/1/--3  
MS 10++4(-5$^{\circ}$) K388 it/h/x/10/6/++4 in hospital, cathode problems
MS 10-+4(-5$^{\circ}$) K 48 it/h/x/10/1/-+4  
MS 10+-4(-5$^{\circ}$) K405 it/h/x/10/1/+-4  
MS 10--4(-5$^{\circ}$) K 51 it/h/x/10/2/--4  

MS 10++5(0$^{\circ}$)

K160 it/h/x/10/3/++5  
MS 10-+5(0$^{\circ}$) K140 it/h/x/10/3/-+5  
MS 10+-5(0$^{\circ}$) K173 it/h/x/10/3/+-5  
MS 10--5(0$^{\circ}$) K142 it/h/x/10/3/--5  
MS 10++6(+5$^{\circ}$) K407 it/h/x/10/3/++6  
MS 10-+6(+5$^{\circ}$) K 81 it/h/x/10/4/-+6 disconnected, cathode problems
MS 10+-6(+5$^{\circ}$) K399 it/h/x/10/4/+-6  
MS 10--6(+5$^{\circ}$) K 43 it/h/x/10/3/--6  

MS 10++7(+5$^{\circ}$)

K387 it/h/x/10/4/++7  
MS 10-+7(+5$^{\circ}$) K 80 it/h/x/10/3/-+7  
MS 10+-7(+5$^{\circ}$) K409 it/h/x/10/3/+-7  
MS 10--7(+5$^{\circ}$) K 49 it/h/x/10/4/--7  
MS 10++8(0$^{\circ}$) K161 it/h/x/10/4/++8  
MS 10-+8(0$^{\circ}$) K141 it/h/x/10/4/-+8  
MS 10+-8(0$^{\circ}$) K167 it/h/x/10/4/+-8 used to have problems...
MS 10--8(0$^{\circ}$) K154 it/h/x/10/4/--8  

MS11
chamber label (new) wafer ID slow control channel remark
MS 11++1(0$^{\circ}$) K460 it/h/x/11/1/++1  
MS 11-+1(-5$^{\circ}$) K170 it/h/x/11/1/-+1  
MS 11+-1(0$^{\circ}$) K24 it/h/x/11/1/+-1  
MS 11--1(0$^{\circ}$) K159 it/h/x/11/1/--1  
MS 11-+2(0$^{\circ}$) K464 it/h/x/11/1/++2  
MS 11-+2(0$^{\circ}$) K131 it/h/x/11/1/-+2  
MS 11--2(-5$^{\circ}$) K68 it/h/x/11/1/+-2  
MS 11--2(-5$^{\circ}$) K190 it/h/x/11/1/--2  

MS 11-+3(+5$^{\circ}$)

K74 it/h/x/11/2/++3  
MS 11-+3(+5$^{\circ}$) K415 it/h/x/11/2/-+3  
MS 11--3(0$^{\circ}$) K444 it/h/x/11/2/+-3  
MS 11--3(0$^{\circ}$) K397 it/h/x/11/2/--3  
MS 11-+4(0$^{\circ}$) K101 it/h/x/11/2/++4  
MS 11-+4(0$^{\circ}$) K413 it/h/x/11/2/-+4  
MS 11--5(+5$^{\circ}$) K33 it/h/x/11/2/+-4  
MS 11--4(+5$^{\circ}$) K150 it/h/x/11/2/--4  

MS12
chamber label (new) wafer ID slow control channel remark
MS 12++1(0$^{\circ}$) K45 it/h/x/12/1/++1  
MS 12-+1(-5$^{\circ}$) K420 it/h/x/12/1/-+1 GEM short
MS 12+-1(-5$^{\circ}$) K412 it/h/x/12/1/+-1  
MS 12--1(0$^{\circ}$) K441 it/h/x/12/1/--1  
MS 12++2(-5$^{\circ}$) K152 it/h/x/12/1/++2 chamber replaced
MS 12-+2(0$^{\circ}$) K446 it/h/x/12/1/-+2 GEM short removed
MS 12+-2(0$^{\circ}$) K419 it/h/x/12/1/+-2  
MS 12--2(-5$^{\circ}$) K440 it/h/x/12/1/--2  

MS 12++3(0$^{\circ}$)

K159 it/h/x/12/2/++3  
MS 12-+3(+5$^{\circ}$) K197 it/h/x/12/2/-+3  
MS 12+-3(+5$^{\circ}$) K95 it/h/x/12/2/+-3  
MS 12--3(-5$^{\circ}$) K442 it/h/x/12/1/--3 frequent GEM-sparks
MS 12++4(+5$^{\circ}$) K391 it/h/x/12/2/++4  
MS 12-+4(0$^{\circ}$) K418 it/h/x/12/2/-+4  

MS 12+-5(0$^{\circ}$)

K27 it/h/x/12/2/+-4  
MS 12--4(+5$^{\circ}$) K445 it/h/x/12/2/--4  

MS13
chamber label (new) wafer ID slow control channel remark
MS 13++1(0$^{\circ}$) K187 it/h/x/13/1/++1  
MS 13-+1(0$^{\circ}$) K163 it/h/x/13/2/-+1  
MS 13+-1(0$^{\circ}$) K395 it/h/x/13/2/+-1  
MS 13--1(0$^{\circ}$) K 54 it/h/x/13/1/--1  
MS 13++2(0$^{\circ}$) K203 it/h/x/13/2/++2  
MS 13-+2(0$^{\circ}$) K123 it/h/x/13/1/-+2  
MS 13+-2(0$^{\circ}$) K408 it/h/x/13/1/+-2  
MS 13--2(0$^{\circ}$) K142 it/h/x/13/2/--2  

MS 13++3(-5$^{\circ}$)

K175 it/h/x/13/1/++3  
MS 13-+3(-5$^{\circ}$) K177 it/h/x/13/2/-+3  
MS 13+-3(-5$^{\circ}$) K390 it/h/x/13/2/+-3  
MS 13--3(-5$^{\circ}$) K 73 it/h/x/13/!/--3 chamber was changed

MS 13++4(-5$^{\circ}$)

K386 it/h/x/13/2/++4  
MS 13-+4(-5$^{\circ}$) K 57 it/h/x/13/1/-+4  
MS 13+-4(-5$^{\circ}$) K121 it/h/x/13/1/+-4  
MS 13--4(-5$^{\circ}$) K166 it/h/x/13/5/--4 chamber was changed

MS 13++5(0$^{\circ}$)

K200 it/h/x/13/3/++5  
MS 13-+5(0$^{\circ}$) K182 it/h/x/13/3/-+5  
MS 13+-5(0$^{\circ}$) K199 it/h/x/13/3/+-5  
MS 13--5(0$^{\circ}$) K156 it/h/x/13/3/--5  
MS 13++6(+5$^{\circ}$) K183 it/h/x/13/6/++6 dead, cathode problems (curr. $>$ 180$\mu$A)

MS 13-+6(+5$^{\circ}$)

K165 it/h/x/13/4/-+6  
MS 13+-6(+5$^{\circ}$) K389 it/h/x/13/4/+-6  
MS 13--6(+5$^{\circ}$) K157 it/h/x/13/3/--6  

MS 13++7(+5$^{\circ}$)

K398 it/h/x/13/4/++7  
MS 13-+7(+5$^{\circ}$) K 35 it/h/x/13/3/-+7  
MS 13+-7(+5$^{\circ}$) K393 it/h/x/13/3/+-7  
MS 13--7(+5$^{\circ}$) K174 it/h/x/13/4/--7  
MS 13++8(0$^{\circ}$) K147 it/h/x/13/4/++8  
MS 13-+8(0$^{\circ}$) K171 it/h/x/13/4/-+8  
MS 13+-8(0$^{\circ}$) K 94 it/h/x/13/4/+-8  
MS 13--8(0$^{\circ}$) K151 it/h/x/13/4/--8  

MS14
chamber label (new) wafer ID slow control channel remark
MS 14-+1(0$^{\circ}$) K227 it/h/x/14/2/-+1 GEM short
MS 14--1(0$^{\circ}$) K225 it/h/x/14/1/--1  
MS 14-+2(0$^{\circ}$) K223 it/h/x/14/!/-+2 GEM short
      chamber not useable
MS 14--2(0$^{\circ}$) K226 it/h/x/14/!/--2 GEM short
      chamber not useable

MS 14-+3(-5$^{\circ}$)

K232 it/h/x/14/!/-+3 GEM short
      chamber not useable
MS 14--3(-5$^{\circ}$) K246 it/h/x/14/1/--3  
MS 14-+4(-5$^{\circ}$) K250 it/h/x/14/!/-+4 cathode shorts
      chamber not useable
MS 14--4(-5$^{\circ}$) K234 it/h/x/14/!/--4 GEM short
      chamber not useable

MS 14-+5(+5$^{\circ}$)

K239 it/h/x/14/3/-+5  
MS 14--5(+5$^{\circ}$) K247 it/h/x/14/2/--5  
MS 14-+6(+5$^{\circ}$) K242 it/h/x/14/2/-+6  
MS 14--6(+5$^{\circ}$) K238 it/h/x/14/3/--6  
The readout of MS14- has been damaged by LV (HELIXes dead)

MS15
chamber label (new) wafer ID slow control channel remark
MS 15--1(0$^{\circ}$) K273 it/h/x/15/2/--1 in training
MS 15-+1(0$^{\circ}$) K262 it/h/x/15/2/-+3 in training
MS 15--2(0$^{\circ}$) K999 it/h/x/15/2/--2 in training

MS 15--3(-5$^{\circ}$)

K291 it/h/x/15/2/--3 in training
MS 15-+3(-5$^{\circ}$) K231 it/h/x/15/1/-+3 in training
MS 15--4(-5$^{\circ}$) K292 it/h/x/15/1/--4 in training

MS 15--5(+5$^{\circ}$)

K277 it/h/x/15/1/--5 in training
MS 15--6(+5$^{\circ}$) K271 it/h/x/15/1/--6 in training



Carsten Krauss
2000-07-13